Downloads

This page contains all the downloads available on this website.

Quality Documents

  • Eland BV ISO14001 Certificate (0.5MB)
    Eland Cables has achieved the prestigious ISO 14001 accreditation, illustrating our current and future commitment to minimising our environmental impact.
  • Eland BV ISO9001 Certificate (0.5MB)
    Eland Cables is audited on a regular basis by Bureau Veritas Certification UK to ensure that we consistently achieve the levels of service and quality required by our customers. We first attained accreditation in 1995.
  • Eland Cables' UVDB Certificate (156kb)
    The UVDB registration system provides utilities companies with a database of audited, pre-qualified suppliers. Eland Cables has been qualified since 2000.
  • Eland Cables RoHS Conformity (121kb)
    Declaration of RoHS Conformity from Eland Cables' Quality Department.
  • Eland Link Up Certificate (1.15MB)
    Eland has been included in Link-up, the UK rail industry supplier qualification scheme, providing registration, qualification and audit process for suppliers since 2000.
  • Eland Cables Environmental Policy (137kb)
    Eland Cables is committed to minimising pollution and making sure that the business has a minimal impact on the environment.
  • Eland Cables Quality Policy (134kb)
    Eland Cables Limited has implemented a quality management system to meet the requirements of BS EN ISO 9001:2000. Our quality management system assesses the quality systems and/or quality performance of our suppliers.
  • FireForce Cable LPCB Certification (0.6MB)
    Eland Cables has been given LPCB approval for its FireForce Cable. This cable has been approved since May 2007.

Product Datasheets

  • 11kV XLPE LSZH Cables (265kb)
    Power cables for power networks, underground, outdoors and in cable ducting. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.
  • 11kV XLPE PVC Cables (261kb)
    Power cables for power networks, underground, outdoors and in cable ducting.
  • 33kV XLPE Cables (243kb)
    Power cables for power networks, underground, outdoors and in cable ducting.
  • 218-Y Flexible Cable (H03VVF) (163kb)
    Light duty cable for use in domestic premises, kitchens and offices. For use with light portable appliances such as radios, table lamps and office machines.
  • 309-Y Cable H05V2V2-F (195kb)
    Supply leads for use as 318-Y but particularly for use in high temperature zones, for internal wiring or supply cords to electrical apparatus. Not suitable for outdoor use.
  • 318-B LSZH Cable (182kb)
    Used as an indoor general wiring cable primarily for installations in public areas. Examples include use on pendant lighting drops or as a general
    supply lead within hospital or airport projects.
  • 318TQ Cable H05BN4F (190kb)
    Flexible cords suitable for use in domestic premises, kitchens and offices. Also suitable for use in hot situations such as immersion heaters. Good resistance to oil and grease.
  • 318-Y Cable (195kb)
    For use in household appliances such as washing machines, spin dryers and refrigerators. Generally unsuitable for outdoor use or industrial applications.
  • 0361TQ Black Welding Cable (206kb)
    For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.
  • 0361TQ Orange Welding Cable (193kb)
    For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.
  • 2192Y Cables (159kb)
    Used as an indoor general wiring cable primarily for installations in public areas. Examples include use on pendant lighting drops or as a general supply lead.
  • 2491B / 6701B Flexible Cable (H05ZK / H07ZK) (153kb)
    In pipes or ducts and internal wiring of appliances with maximum operating temperatures of 90°C, and generally in areas (such as public and government buildings) where smoke and toxic fumes may cause a threat to life and equipment. The cables produce no corrosive gasses when burnt which is particularly important where electronic equipment is installed.
  • 2491X Flexible Cable (H05V-K H07V-K) (144kb)
    Designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.
  • 6181Y Double Insulated Surface Wiring Cable (251kb)
    Fixed installation in dry or damp areas for domestic and light industrial wiring.
  • 6381LSZH Cables (189kb)
    Suitable for D.C. power supplies on Telecom equipment and power applications where flexibility is required. The cables produce no corrosive gases when burnt which is important where electronic equipment is installed.
  • H07BN4-F Cable (6381TQ) (251kb)
    For connecting equipment such as pumps, generators and lighting to the mains supply and generally for use in arduous industrial environments where good flexibility and resistance to mechanical abrasion is essential.
  • 6381Y Cables (191kb)
    Suitable for D.C. power supplies on Telecom equipment and power applications where flexibility is required.
  • 6491B Conduit Wiring Cable (H07Z-R) (261kb)
    Suitable for use in conduit and for fixed, protected installation. In particular for installation where fire, smoke emission and toxic fumes create a potential threat.
  • 6491X Conduit Wiring Cable (H07V-R) (258kb)
    Suitable for use in conduit and for fixed, protected installation.
  • Aluminium Power Cables (172kb)
    BR880 solid sector shaped conductors for trackside signalling power supplies.
  • Arctic Grade Cable (193kb)
    Designed to withstand severe external temperatures remaining flexible at temperatures as low as -20°C. Arctic Grade PVC mains cords generally manufactured to BS6500 will remain flexible at temperatures down to minus 20°C making them particularly suitable for outdoor applications and for use where flexibility is required at sub zero temperatures. At normal temperatures the cable is very limp and flexible, offering some of the characteristics usually found in elastomeric cables.
  • Bare Conductor Cable (299kb)
    To be used for the purpose of screening telecommunication cables from electrical interference.
  • Cat5E FTP PE GSWB LSZH Cables (150kb)
    A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5 E is recommended for all new installations, supports a frequency range of up to 100MHz and isdesigned for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).
  • Cat5E UTP PE External Cable (170kb)
    A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5E is recommended for all new installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet). Cat 5E UTP is suitable for outdoor use.
  • Cat5E UTP LSZH Cable (147kb)
    A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5E is recommended for all new installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).
  • Cat5E UTP PVC Cable (182kb)
    A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 5E is recommended for all new installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).
  • Cat6 LSZH Cable (136kb)
    A multipair (usually 4 pair) high performance cable that consists of twisted pair conductors, used mainly for data transmission. Category 6 is recommended for all new installations, supports a frequency range of up to 100MHz and is designed for transmission speeds of up to 1 gigabit per second (Gigabit Ethernet).
  • Coaxial Cable Type RG URM Composite (146kb)
    Coaxial cable used for low power video and video signal connections.
  • Coaxial BT3002/RA7000 Eq. Cable (174kb)
    Manufactured to BT specifications and used for interconnecting equipment.
  • Coaxial Cable Type CT (153kb)
    Ideal for professional TV and CCTV system installations including digital satellite, terrestrial and Cable TV.
  • Coil End Lead Cable (244kb)
    Coil leads are used mainly in electrical machinery and panel wiring. The HOFR sheath resists oil and varnish and the stranding is designed as a compromise between flexibility and positional stability. Also suitable as an alternative to tri-rated and bi-rated cable in certain applications.
  • Copper Trackside Cable (248kb)
    Suitable for installation in trackside concrete cable troughing, buried duct route or for direct burial installations.
  • Curly Flex Cable (204kb)
    Intended for use in machinery, lifting platforms, conveyor and transport belts, agricultural equipment, construction machinery or trucks with high chemical, thermal or mechanical stress.
  • CW1128 External Telephone Cable (173kb)
    Cables primarily designed for the interconnection of telephone equipment.
    In addition these cables may be used for interconnection of other communication
    and control equipment or low level signalling applications.
  • CW1128/1198 Telephone Cable (178kb)
    External armoured cable primarily designed for the interconnection of telephone equipment. Suitable for direct burial. UV and moisture resistant. In addition these cables may be used for interconnection of other communication and control equipment or low level signalling applications.
  • CW1308 Internal Telecom Cable (167kb)
    Cables primarily designed for the interconnection of telephone equipment which
    is installed indoors. In addition these cables may be used for the interconnection of other communication and control equipment or low level signalling applications.
  • CY Control Cable (215kb)
    Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
  • CY LSZH Control Cable (201kb)
    For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
  • Eland Extraflex Cable (165kb)
    For industrial uses, secondary side connection of power sources for metal arc welding, heavy duty portable supply in dry, wet and oil environments. For motor connections, generators transformers where flexible connections are required and all fixed wiring 0.6/1kV power applications.
  • Elandflex Cable (181kb)
    Highly flexible single core conductors with a great variety of industrial applications, such as cable harnesses, panel wiring and power generation.
  • Elevator Flatform Cable (184kb)
    Cables for elevators (Internal and Panoramic).
  • Festoon Lighting Internal Cable (135kb)
    Use Indoors.
  • Festoon Lighting External Cable (168kb)
    Use Outdoors.
  • Fibre Trackside Cable (174kb)
    Fibre communications cable for use in high traffic and data rate requirements.
  • FireForce Fire Performance Cable PH30 (297kb)
    For fixed installation typically in fire alarm and emergency lighting circuits where circuit integrity must be maintained. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
  • H01N2D Welding Cable (152kb)
    H01N2D cables is used in the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.
  • H01N2E Welding Cable (152kb)
    For the transmission of high currents from the electric welding machine to the welding tool. Suitable for flexible use under rough conditions, on assembly lines and conveyor systems, in machine tool and motor car manufacturing, ship building, for manually and automatically operated line and spot welding machines.
  • H07RN-F Cable (318kb)
    These cables are designed to provide high flexibility and have the capacity to withstand weather, oils/greases, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.
  • High Temperature PTFE Cable (131kb)
    Equipment wire for high performance aerospace applications. PTFE wires are used in severe environmental conditions.
  • High Temperature Silicone Cable (160kb)
    Typical industrial applications include food processing, packaging, refrigeration,
    furnaces and lighting.
  • MV Power Cables (155kb)
    6.35/11kV, 12.7/22kV and 19/33kV cable used to distribute three phase a.c. electrical power supplies at nominal system voltages of 11kV, 22kV and 33kV to traction substations on D.C. Electrified lines. 25/44kV single core cable used
    to carry electrical power supplies from trackside switching stations to the overhead line equipment on A.C. Electrified lines. 25/44kV two core concentric cables used to deliver single phase electrical power supplies, typically, to feeder stations on A.C. Electrified lines.
  • Individually Screened Multi-Pair Cable (170kb)
    Audio, instrumentation and computer cable.
  • Screening Conductor Cable LSZH (166kb)
    150 and 250mm² screening conductor run parallel to communications cables to provide effective ‘’zonal’’ screening.
  • Multi-Core Screened Data Cables to Defence Standard 61/12 part 4 (141kb)
    These multicore flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.
  • Multi-Core Screened Data Cables to Defence Standard 61/12 part 5 (179kb)
    These multicore flexible cables are designed for high density wiring between components and within instruments and electronic equipment. They are extensively used in aircraft, process control systems, computers, data processors, military vehicles and military equipment.
  • BS5308 Instrumentation Cable Part 1 Type 1 (202kb)
    BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.
  • BS5308 Instrumentation Cable Part 1 Type 2 (214kb)
    BS5308 cables are used to carry voice and data services, they also serve as the interconnection between electrical equipment and instruments, particularly in and around process plants, where transducer generated signals are transmitted through to panels, controllers and other devices.
  • NSGAFOU Cable (197kb)
    Single core cable for use in switch cabinets, wiring of devices, trains and buses as well as in dry rooms.
  • NSHTOU Cable (204kb)
    For use in hoists, transporting machines and conveyors, in power chains, as drum and drag cables and as hawsers. Wherever cables are reeled, unreeled, guided by roller trains or similar.
  • NYY-J Cable (169kb)
    Energy cables for use in power stations, industrial and electric supply companies. To be used in the open air, underground, indoors and in cable ducting.
  • Overall Foil and Braid Screened Cable (123kb)
    Audio, instrumentation & computer cable for use in electronics.
  • Overall Screened Multi-Core Cable (139kb)
    Cables used for instrumentation control & computer applications.
  • Overall Screened Multi-Pair Cable (172kb)
    Cables used for instrumentation control & computer applications.
  • Overall Screened Single Pair Cable (163kb)
    Audio, instrumentation & computer cable for use in electronics.
  • Points Heating Cable (171kb)
    Designed for power distribution in points heating systems. These heavy duty cables offer protection from abrasion and mechanical impact whilst maintaining flexibility to ease installation.
  • SCADA / Pilot Cable (179kb)
    Paired core compound filled supervisiory cables for modem based supervisory systems operating in the VF range 300 to 3000 Hz.
  • Screening Conductor Cable PVC (168kb)
    To be used for the purpose of screening telecommunication cables from electrical interference.
  • Signalling Cable Type A1, A2, A3 (174kb)
    Light Duty LSZH sheathed single and multi-core generally for internal use. Smooth sheath suitable for installation in ducting.
  • Signalling Cable Type B1, B2 (190kb)
    Heavy Duty EPR insulated and High Density PCP sheathed single, twin and multicore cables.
  • Signalling Cable Type C1, C2, C3 (161kb)
    Heavy Duty Signalling cable suitable for tails.
  • Signalling Cable Type D1, D2 (189kb)
    LSZH single, twin and multicore cables.
  • Signalling Cable Type E1, E2, E3 (152kb)
    LSZH signalling cable suitable for tails.
  • Steel Wire Armoured (SWA) LSZH Cable (214kb)
    Power and auxiliary control cables for power networks, underground, outdoors, indoors and in cable ducting. For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
  • Steel Wire Armoured (SWA) BS5467 Cable PVC (315kb)
    Power and auxiliary control cables for power networks, underground, outdoors, indoors and in cable ducting.
  • SY Control Cable (259kb)
    Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
  • Track Feeder Cable (168kb)
    Eland Cables is a market leader in the supply Of Network Rail approved cables for Power, Signalling, Overhead and Telecommunications applications. Eland is an ISO9001 and Link-up approved supplier. Eland Cables is a leading international cable supplier.
  • Tri-rated Cable (215kb)
    Designed for use in the switch control, relay and instrumentation panels of power switchgear and for purposes such as internal connectors in rectifier equipment, motor starters and controllers.
  • Twinflex Battery Cable (221kb)
    For indoors and outdoors, in dry as well as wet location on motorised vehicles, or battery powered equipment such as fork lifts and field conveyors. Also in high quality booster cables.
  • Twin Datalink Cable (142kb)
    Interconnecting cable for Solid State Interlocking (SSI) systems.
  • Unscreened Single Pair Cable (168kb)
    Audio, instrumentation and computer cable for use in electronics.
  • YY Control Cable (269kb)
    Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
  • YY LSZH Control Cable (224kb)
    For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use in conditions of light mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors.
  • Individually Screened Multi-Pair Low Cap RS422 Cables (Belden Equivalent) (159kb)
    Eland’s comprehensive range of LSF Belden equivalent data cables includes individually screened multi-pair versions in 2 & 3 pair and 24AWG & 22AWG configurations. We also stock 2 pair 22AWG (8723) external / duct (PE sheath) and armoured (SWA/PE).
  • Cat 5E FTP Cable (181kb)
    Eland supplies a comprehensive range of Cat5E cables, including Cat 5E FTP Cable, and cables suitable for internal and external use whilst also stocking a Cat5E version suitable for direct burial. Eland cables is an international market leader in the supply of electrical cables.
  • Insulated Tabs and Receptacles (95kb)
  • Alarm Cable (268kb)
    Flexible cable used for the wiring of burglar alarms and other low voltage circuits.
  • 624-B LSZH Twin and Earth (117kb)
    Domestic wiring cable for the surface wiring of sockets and lighting where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where mechanical damage would not be an issue. Suitable for laying in conduit or trunking where mechanical protection is required.
  • Twinaxial Cable Type 9207LSF (222kb)
    Paired computer cables. These cables were originally developed for I/O switching and process control applications and are now widely used in commercial applications for building management systems.
  • Twinaxial Cable Type 9272LSF (173kb)
    Paired computer cables. These cables were originally developed for I/O switching and process control applications and are now widely used in commercial applications for building management systems.
  • Cable Gland BW (89kb)
  • Copper Tube Pin Terminals (100kb)
  • Cable Gland CW (95kb)
  • Cable Gland CXT (69kb)
  • Cable Gland Matching (84kb)
  • Cable Ties (80kb)
  • Long Palm 2 Hole Fixing Lugs (88kb)
  • Cord End Terminals (107kb)
  • Dual Entry Cord End Terminals (91kb)
  • Uninsulated Cord End Terminals (100kb)
  • Easi-Lok Cable Markers (71kb)
  • Easi-Lok Cable Markers Applicators (60kb)
  • Easi-Mark Cable Markers (69kb)
  • Easi-Mark Cable Marker Applicators (60kb)
  • Easi-Route Cable Markers and Carrier Strips (68kb)
  • FCCS Single Handed Action Triple Action Cutter (79kb)
  • Crimp Terminal Tooling (78kb)
  • Cable Connectors (84kb)
  • Heavy Duty Cable Connectors (78kb)
  • Heat Shrink (98kb)
  • FCRC Copper and Aluminium Cable Cutter (87kb)
  • Cable Gland CX (74kb)
  • Neoprene Sleeving (83kb)
  • Braided Sleeving (87kb)
  • Plier Action Tool (77kb)
  • FCCC Copper and Aluminium Cable Cutter (82kb)
  • Ratchet Action Tool (78kb)
  • Tool for Cable Ties (85kb)
  • Hand Tooling for Copper Tube Terminals (92kb)
  • Copper Tube Terminals (82kb)
  • PVC Sleeving (82kb)
  • FTN Screening Conductor Cable PVC (143kb)
    To be used for the purpose of screening telecommunication cables from electrical interference.
  • Uninsulated Copper Brazen Sheet Terminals (128kb)
  • Twinaxial 9207 9272 9463 Cable (225kb)
    Eland’s comprehensive range of LSF Belden alternative data cables now includes low loss twin-axials. Eland Cables is an international market leader in the supply of cables.
  • Curly Flex PVC Cable (190kb)
    For use in domestic appliances, ceiling to display or cash desk equipment and indoor lighting features.
  • Curly Flex PUR Cable (155kb)
    For use in power tools, hoists, scissor lifts and roller doors within harsh industrial environments.
  • Guardian Cable (210kb)
    This mechanically protected 600/1000V LSZH fixed wiring cable is user friendly, lightweight and easy to install. Guardian Cable offers greatly reduced electrical interference through the use of an aluminium screen which also provides impact resistance. Typically used within walls, partitions and building voids, demand for this range will increase following the recent issue 17th Edition IEE Wiring Regulations and, in particular, the clause covering nail penetration capabilities of electrical cables.
  • RV-K Powerflex Cable (312kb)
    A flexible power and control cable designed for fixed applications. Manufactured with flexible conductors in order to facilitate installations with sinuous courses.
  • Intemp 250 Cable (176kb)
    This high performance cable is designed to operate under more arduous high temperature conditions, providing moisture resistance, toughness, flexibility and a continous conductor operating temperature of 250ºC.
  • RIA21 Cable (219kb)
    Cables are designed for use in protected or exposed installation on traction & rolling stock within vehicles. May also find application in the connection of coil winding and flexible power leads.
  • RZ1-K LSZH Cable (342kb)
    For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment.
    A flexible power and control cable designed for fixed applications. Manufactured with flexible conductors
    in order to facilitate installations with sinuous courses.
  • H07ZZ-F Cable (290kb)
    For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. These cables are designed to provide high flexibility and have the capacity to withstand weather, oils/greases, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.

General Documents

Contact

Contact our sales team for product or pricing information on

Tel +44 (0)20 7241 8787
Fax +44 (0)20 7241 8700