H07RN-F Cable

- Eland Product Group:
- A6G and A5G
- Application:
- These cables are designed to provide high flexibility and have
the capacity to withstand weather,
oils/greases, mechanical and thermal stresses. Applications include handling equipment, mobile power supplies, worksites, stage and audio visual equipment, port areas and dams. Also for use in drainage and water treatment, cold environments and severe industrial environments.
Read more about H07RN-F Cables and their applications. - Standards:
- BS7919, CENELEC HD22.4 S4
- Conductor:
- Class 5 flexible plain copper to BS EN 60228:2005 (previously BS6360)
- Insulation:
- EPR (Ethylene Propylene Rubber) Type EI4 to BS7655
- Sheath:
- PCP (Polychloroprene) Type EM2 to BS7655
- Sheath Colour:
- Black
- Voltage Rating:
- 450/750V
- Temperature Rating:
- Conductor operating temperature -30°C to +60°C (85°C max)
- Minimum Bending Radius:
Up to 25mm²: 6 x overall diameter
Above 25mm²: 8 x overall diameter- Core Identification:
2 Cores: Blue, Brown
3 Cores: Green/Yellow, Blue, Brown
4 Cores: Green/Yellow, Brown, Black, Grey
5 Cores: Green/Yellow, Blue, Brown, Black, Grey
6 Cores and above: Black with White numerals, Green/Yellow
Specifications Data
Download detailed H07RN-F Cable specifications as a PDF file (318kb)
| No. of Cores x Nominal Cross Sectional Area# x mm² | Nominal Thickness of Insulationmm | Nominal Overall Diametermm | Nominal Weightkg/Km | FCGA2 GlandBrass | FCGA2PL GlandPlastic |
|---|---|---|---|---|---|
| 1 x 1.5 | 0.8 | 5.9 | 50 | 20/16 | 20S |
| 1 x 2.5 | 0.9 | 6.6 | 65 | 20/16 | 20S |
| 1 x 4.0 | 1.0 | 7.8 | 115 | 20/16 | 20 |
| 1 x 6.0 | 1.0 | 9.0 | 142 | 20 | 20 |
| 1 x 10.0 | 1.2 | 10.8 | 219 | 20S | 20 |
| 1 x 16.0 | 1.2 | 12.1 | 302 | 20 | 20L |
| 1 x 25.0 | 1.4 | 14.1 | 436 | 25 | 25 |
| 1 x 35.0 | 1.4 | 15.9 | 567 | 25 | 25 |
| 1 x 50.0 | 1.6 | 18.5 | 790 | 25 | 32 |
| 1 x 70.0 | 1.6 | 21.0 | 1050 | 32 | 32 |
| 1 x 95.0 | 1.8 | 23.9 | 1350 | 32 | 32 |
| 1 x 120.0 | 1.8 | 25.8 | 1650 | 32 | 40 |
| 1 x 150.0 | 2.0 | 28.6 | 2050 | 40 | 40 |
| 1 x 185.0 | 2.2 | 31.5 | 2450 | 40 | 40 |
| 1 x 240.0 | 2.4 | 35.1 | 3200 | 50S | 50 |
| 1 x 300.0 | 2.6 | 38.7 | 3900 | 50 | - |
| 1 x 400.0 | 2.8 | 43.5 | 5000 | 50 | - |
| 1 x 500.0 | 3.0 | 47.5 | 6200 | 63S | - |
| 1 x 630.0 | 3.0 | 51.5 | 7650 | 63 | - |
| 2 x 1.0 | 0.8 | 8.6 | 95 | 20S | 20 |
| 2 x 1.5 | 0.8 | 9.6 | 115 | 20S | 20 |
| 2 x 2.5 | 0.9 | 11.2 | 140 | 20S | 20 |
| 2 x 4.0 | 1.0 | 13.2 | 302 | 20 | 20L |
| 2 x 6.0 | 1.0 | 15.6 | 400 | 25 | 25 |
| 2 x 10.0 | 1.2 | 20.6 | 750 | 32 | 32 |
| 2 x 16.0 | 1.2 | 23.3 | 990 | 32 | 32 |
| 2 x 25.0 | 1.4 | 27.4 | 1400 | 40 | 40 |
| 3 x 1.0 | 0.8 | 9.3 | 115 | 20S | 20 |
| 3 x 1.5 | 0.8 | 10.3 | 140 | 20S | 20 |
| 3 x 2.5 | 0.9 | 12.0 | 200 | 20 | 20 |
| 3 x 4.0 | 1.0 | 14.1 | 360 | 25 | 25 |
| 3 x 6.0 | 1.0 | 16.6 | 490 | 25 | 25 |
| 3 x 10.0 | 1.2 | 22.1 | 900 | 32 | 32 |
| 3 x 16.0 | 1.2 | 24.8 | 1200 | 32 | 32 |
| 3 x 25.0 | 1.4 | 29.3 | 1700 | 40 | 40 |
| 3 x 35.0 | 1.4 | 32.9 | 2200 | 50S | 50 |
| 3 x 50.0 | 1.6 | 38.5 | 3100 | 50 | - |
| 3 x 70.0 | 1.6 | 43.6 | 4130 | 63S | - |
| 3 x 95.0 | 1.8 | 50.0 | 5300 | 63 | - |
| 3 x 120.0 | 1.8 | 53.9 | 6700 | 63 | - |
| 3 x 150.0 | 2.0 | 59.9 | 8000 | 75S | - |
| 3 x 185.0 | 2.2 | 65.9 | 9700 | 75 | - |
| 3 x 240.0 | 2.4 | 74.7 | 12400 | 90 | - |
| 3 x 300.0 | 2.6 | 83.2 | 15300 | - | - |
| 4 x 1.0 | 0.8 | 10.3 | 140 | 20S | 20 |
| 4 x 1.5 | 0.8 | 11.4 | 170 | 20S | 20 |
| 4 x 2.5 | 0.9 | 13.2 | 245 | 20 | 20L |
| 4 x 4.0 | 1.0 | 15.5 | 460 | 25 | 25 |
| 4 x 6.0 | 1.0 | 18.5 | 610 | 25 | 32 |
| 4 x 10.0 | 1.2 | 24.1 | 1100 | 32 | 32 |
| 4 x 16.0 | 1.2 | 27.1 | 1500 | 40 | 40 |
| 4 x 25.0 | 1.4 | 32.5 | 2310 | 50S | 50 |
| 4 x 35.0 | 1.4 | 36.5 | 2800 | 50S | 50 |
| 4 x 50.0 | 1.6 | 42.6 | 3910 | 50 | - |
| 4 x 70.0 | 1.6 | 48.6 | 5200 | 63 | - |
| 4 x 95.0 | 1.8 | 56.0 | 6810 | 75S | - |
| 4 x 120.0 | 1.8 | 59.9 | 8200 | 75S | - |
| 4 x 150.0 | 2.0 | 66.8 | 10200 | 75 | - |
| 4 x 185.0 | 2.2 | 73.5 | 12300 | 90 | - |
| 4 x 240.0 | 2.4 | 83.5 | 15900 | - | - |
| 4 x 300.0 | 2.6 | 92.8 | 19600 | - | - |
| 5 x 1.5 | 0.8 | 12.5 | 210 | 20 | 20L |
| 5 x 2.5 | 0.9 | 14.5 | 305 | 25 | 25 |
| 5 x 4.0 | 1.0 | 17.2 | 560 | 25 | 25 |
| 5 x 6.0 | 1.0 | 20.5 | 750 | 32 | 32 |
| 5 x 10.0 | 1.2 | 26.5 | 1300 | 40 | 40 |
| 5 x 16.0 | 1.2 | 30.1 | 1800 | 40 | 40 |
| 5 x 25.0 | 1.4 | 36.1 | 2600 | 50S | 50 |
| 5 x 35.0 | 1.4 | 40.5 | 3590 | 50 | - |
| 5 x 50.0 | 1.6 | 47.3 | 4550 | 63S | - |
| 7 x 1.5 | 0.8 | 16.5 | 335 | 25 | 25 |
| 7 x 2.5 | 0.9 | 18.5 | 475 | 25 | 32 |
| 7 x 4.0 | 1.0 | 21.6 | 770 | 32 | 32 |
| 7 x 6.0 | 1.0 | 25.7 | 1090 | 32 | 40 |
| 7 x 10.0 | 1.2 | 31.6 | 1710 | 40 | 40 |
| 7 x 16.0 | 1.2 | 35.7 | 2330 | 50S | 50 |
| 7 x 25.0 | 1.4 | 43.2 | 3560 | 50 | - |
| 8 x 1.5 | 0.8 | 17.7 | 385 | 25 | 25 |
| 8 x 2.5 | 0.9 | 20.3 | 560 | 32 | 32 |
| 8 x 4.0 | 1.0 | 23.5 | 900 | 32 | 32 |
| 12 x 1.5 | 0.8 | 19.5 | 495 | 25 | 32 |
| 12 x 2.5 | 0.9 | 22.5 | 710 | 32 | 32 |
| 12 x 4.0 | 1.0 | 26.2 | 1180 | 32 | 40 |
| 18 x 1.5 | 0.8 | 23.0 | 700 | 32 | 32 |
| 18 x 2.5 | 0.9 | 26.6 | 1020 | 40 | 40 |
| 18 x 4.0 | 1.0 | 31.0 | 1690 | 40 | 40 |
| 21 x 1.5 | 0.8 | 25.5 | 885 | 32 | 40 |
| 21 x 2.5 | 0.9 | 29.7 | 1290 | 40 | 40 |
| 27 x 1.5 | 0.8 | 27.5 | 1090 | 40 | 40 |
| 27 x 2.5 | 0.9 | 32.1 | 1590 | 50S | 50 |
| 37 x 1.5 | 0.8 | 31.0 | 1300 | 40 | 50 |
| 37 x 2.5 | 0.9 | 38.7 | 2320 | 50 | - |
| 42 x 1.5 | 0.8 | 34.8 | 1660 | 50S | - |
| 42 x 2.5 | 0.9 | 40.6 | 2430 | 50 | - |