CY LSZH Control Flexible Cable
- Eland Product Group:
- A5B
- Application:
- For installation where fire, smoke emission and toxic fumes create a potential threat to life and equipment. Used as interconnecting cable for measuring, controlling or regulation in control equipment for assembly and production lines, conveyors and for computer units. Suitable for fixed installations or for flexible use when temporarily moved, and in conditions of medium mechanical stress. Can be used outdoors when protected, and in dry or moist conditions indoors. These cables with copper screening are ideally suitable for interference free data and signal transmission in measuring and control technology.
- Standards:
- Generally to BS6500,VDE0250
- Conductor:
- Class 5 flexible plain stranded copper conductors to
BS EN 60228:2005 (previously BS6360), VDE0295, IEC 60228 - Insulation:
- XLPE (Cross-Linked Polyethylene)
- Braiding:
- TCWB (Tinned Copper Wire Braid)
- Sheath:
- LSZH (Low Smoke Zero Halogen)
- Sheath Colour:
- Grey
- Voltage Rating:
- 300/500V
- Temperature Rating:
Fixed: -35°C to +85°C
Flexing: -5°C to +85°C- Minimum Bending Radius:
- 10 x overall diameter
- Core Identification:
- Black with White numbers. (3 cores and above to include Green/Yellow). Coloured cores available.
Specifications Data
Download detailed CY LSZH Control Flexible Cable specifications as a PDF file (192kb)
| No. of Cores x Cross Sectional Area# x mm² | Nominal Overall Diametermm | Nominal Weightkg/Km | FCGCXT Gland |
|---|---|---|---|
| 2 x 0.75 | 6.0 | 54 | 20SS |
| 2 x 1.00 | 6.2 | 60 | 20SS |
| 2 x 1.50 | 6.8 | 70 | 20SS |
| 2 x 2.50 | 8.0 | 104 | 20S |
| 3 x 0.75 | 6.3 | 65 | 20SS |
| 3 x 1.00 | 6.5 | 73 | 20SS |
| 3 x 1.50 | 7.2 | 90 | 20S |
| 3 x 2.50 | 8.6 | 140 | 20S |
| 3 x 4.00 | 9.5 | 175 | 20S |
| 4 x 0.75 | 6.8 | 77 | 20SS |
| 4 x 1.00 | 7.0 | 89 | 20S |
| 4 x 1.50 | 7.8 | 108 | 20S |
| 4 x 2.50 | 9.4 | 173 | 20S |
| 4 x 4.00 | 11.1 | 236 | 20S |
| 4 x 6.00 | 12.8 | 339 | 20 |
| 4 x 10.00 | 16.1 | 502 | 25 |
| 4 x 16.00 | 19.2 | 771 | 25 |
| 4 x 25.00 | 20.2 | 1420 | 32 |
| 4 x 35.00 | 24.4 | 1750 | 32 |
| 5 x 0.75 | 7.3 | 91 | 20S |
| 5 x 1.00 | 7.6 | 105 | 20S |
| 5 x 1.50 | 8.4 | 125 | 20S |
| 5 x 2.50 | 10.0 | 206 | 20S |
| 5 x 4.00 | 12.1 | 288 | 20 |
| 7 x 0.75 | 7.8 | 115 | 20S |
| 7 x 1.00 | 8.4 | 139 | 20S |
| 7 x 1.50 | 9.3 | 160 | 20S |
| 7 x 2.50 | 10.8 | 267 | 20S |
| 12 x 0.75 | 10.1 | 177 | 20S |
| 12 x 1.00 | 10.4 | 207 | 20S |
| 12 x 1.50 | 11.8 | 279 | 20 |
| 18 x 0.75 | 11.6 | 250 | 20 |
| 18 x 1.00 | 12.4 | 295 | 20 |
| 18 x 1.50 | 14.0 | 350 | 25 |